Extend machinery life, reduce operating costs and increase productivity with a Graco G3 today! The G3 Max has a flexible design that works with injector-based and series progressive systems. A cost-effective pump designed to serve multiple markets and applications. Includes one adjustable pump element - standard, plus room for two more. The ultimate in flexibility - for a high value, custom fit on your application.
- Built-in controller with selectable pump on/pump off timer
- Low level indicator provides low warning and shut-down alarm
- Manual run initiates lube cycle on-demand (remote option also available)
- Password protection safeguards settings
- Pre-lube function can initiate lube cycle on start-up
- Up to three pressure or cycle switch inputs to ensure proper lubrication cycles
- Mix/match cycle and pressure switches for custom installations and feedback
- Machine count input - ideally suited for inconsistently used equipment
- Fault indication to external alarms
- Optional Data Management System (DMS) - Work faster and smarter with Graco's exclusive Data Management System (DMS) Find out exactly how your lubrication system is performing and how well it's lubricated Tracks history, provides data protection, upload or download data using a simple USB flash drive.
Technical Specifications
Type | Electric Piston Pump |
---|---|
Application | On-Road Vehicles, Off-Road Equipment |
Compatible Material | Oil |
Fluid Outlet Size (in) | 0.25 |
Fluid Outlet Size (mm) | 6.3500 |
Fluid Outlet Thread Gender | Female |
Fluid Outlet Thread Type | NPSF |
For Use With | 基于注油器的系统, インジェクターベースシステム, Injector-Based Systems, Sistemas basados en inyectores, 递进式递进式系统, 先進的シリーズシステム, Series Progressive Systems, sistemas progresivos en serie |
Includes | 机器计数, マシンカウント, Machine Count, Conteo de la máquina, 泄压阀, ベントバルブ, Vent Valve, válvula de ventilación, DIN 警报输出, DIN アラーム出力, DIN Alarm Output, salida de alarma DIN, 适用于远程装置的 M12 连接, リモート用 M12 接続, M12 Connection for Remote, conexión M12 para control remoto, 低液位, 低レベル, Low Level, nivel bajo |
Maximum NLGI Grade | #2 |
Maximum Working Pressure (bar) | 351.6 |
Maximum Working Pressure (kPa) | 35160 |
Maximum Working Pressure (psi) | 5100 |
Model | G3 |
Power Type | Electric |
Reservoir Size (gal) | 1.06 |
Reservoir Size (L) | 4 |
Series | Max |
Voltage (V ac) | 90-240 |
Weight (lb) | 13.3 |
Wetted Material | Nylon, Trogamid T5004-060, Zinc-Plated Steel, Carbon Steel, Alloy Steel, Stainless Steel, Nitrile Rubber, Bronze, Nickel Plated Alnico, Chemically Lubricated Acetal, Aluminum, PTFE, Grillamid |
Alarm Relay Inductive Maximum Operating Current (A) | 1.5 |
Alarm Relay Inductive Maximum Operating Voltage (VAC) | 250 |
Alarm Relay Inductive Maximum Switching Capacity | 25 VA;30 W |
Alarm Relay Inductive Rated Load (A) | 0.2 |
Alarm Relay Resistive Maximum Operating Current (A) | 3 |
Alarm Relay Resistive Maximum Operating Voltage (VAC) | 250 |
Alarm Relay Resistive Maximum Switching Capacity | 50 VA;60 W |
Alarm Relay Resistive Minimum Permissible Load | 10 µA;10m VDC |
Alarm Relay Resistive Rated Load (A) | 0.4 |
Compatible Metering Device | Series Progressive, Single Line Parallel |
Control Options | Max |
Input Cycle Rate (Hz) | 8 |
Input Impedance | 1.1 |
Input Load Current (mA @ 24 VDC) | 22 |
Input Maximum Off Current (mA) | 1.5 |
Input Maximum Residual Voltage (V) | 4 |
Input Required Switch Type | Normally Open |
Input Response Time (ms) | 60 |
IP Rating | IP69K |
Low Level Carry Current (A) | 1.2 |
Low Level Contact Rating (W) | 10 |
Low Level Switch Rating (VDC) | 200 |
Low Level Switching Current (A) | 0.5 |
Maximum Fill Inlet Pressure (bar) | 344.7 |
Maximum Fill Inlet Pressure (kPa) | 34470 |
Maximum Fill Inlet Pressure (psi) | 5000 |
Maximum Run Time (min) | 30 |
Maximum Voltage (V ac) | 264 |
Minimum cST Grade (cST) | 40 |
Minimum Voltage (V ac) | 88 |
Number of Machine Count Sensor Inputs | 1 |
Number of Pressure and Cycle Sensor Inputs | 3 |
Number of Pump Elements | Up to 3 |
Number of Sensor Inputs | 3, 1 |
Overall Depth (cm) | 25.4 |
Overall Depth (in) | 10 |
Overall Depth (mm) | 254 |
Overall Height (cm) | 36.8 |
Overall Height (in) | 14.5 |
Overall Height (mm) | 368 |
Overall Width (cm) | 23.5 |
Overall Width (in) | 9.25 |
Overall Width (mm) | 235 |
Power Connection Type | DIN |
Pump Output with 0 Spacers (cu in/min) | 0.25 |
Pump Output with 2 Spacers (cu in/min) | 0.12 |
Vent Valve Maximum Operating Current (A) | 2 |
Vent Valve Maximum Operating Power (W) | 48 |
Vent Valve Output Voltage (VDC) | 24 |
Voltage (V) | 90-240 VAC |
Weight (kg) | 6 |
Maximum Working Pressure (MPa) | 35.1 |