{"product_id":"emax-esp15v120y3-208-silent-air-industrial-plus-15hp-3cyl-57cfm-3-phase-208v-2-stage-120-gal-vertical-stationary-electri","title":"EMAX ESP15V120Y3-208 Silent Air Industrial Plus 15HP 3CYL 57CFM 3- Phase 208V 2-Stage 120 Gal. Vertical Stationary Electric Air Compressor-W\/ Pressure Lube Pump , Isolator Pads, Belt Tensioner, Continuous Run, Auto Drain Bundled w\/ 115CFM Refrigerated Air","description":"\u003cp\u003eThe EMAX Silent Air Industrial Plus ESP15V120Y3-208 is a 15 HP, 3-cylinder, two-stage piston air compressor on a 120-gallon vertical stationary tank. It delivers 58 CFM at up to 175 PSI on 208V three-phase power and is bundled with a 115 CFM refrigerated air dryer. With a pressure-lubricated cast iron pump, continuous-run capability, and patented noise suppression, it suits industrial facilities and shops that need high-volume, continuous-duty air with less noise.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSilent Air™ Noise Suppression\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eUp to 50% Quieter:\u003c\/b\u003e The patented Silent Air™ silencer system achieves up to 50% quieter operation, with noise levels at or below conversational volume. Each 10 dBA drop equals a 50% reduction to the human ear.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eIntake Noise Control:\u003c\/b\u003e Noise-reducing baffle plates and high-capacity filter media target intake noise, which is the loudest source of compressor sound. The system provides up to 1000% more filtration than standard setups.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eService-Friendly Design:\u003c\/b\u003e Unlike enclosed cabinet systems, which are costly and restrict service access, the silencer is cost-effective and easy to service.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003ePressure Lubrication Pump\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eGear-Driven Oil Pump:\u003c\/b\u003e A gear oil pump mounted to the rear of the crankshaft generates positive oil pressure. It delivers a continuous flow of oil to each bearing point, reducing friction and wear and keeping bearings cool.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eRifle-Drilled Oil Passages:\u003c\/b\u003e The crankshaft and connecting rods are rifle-drilled so oil flows directly to bearings, piston pins, and other high-friction wear points.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eSpin-On Oil Filter:\u003c\/b\u003e An automotive-style spin-on oil filter keeps oil clean and simplifies maintenance during oil changes. Oil capacity is 3 quarts.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eAnalog Oil Pressure Gauge:\u003c\/b\u003e Operators can monitor oil pressure accurately.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eContinuous-Duty Protection:\u003c\/b\u003e Unlike splash-lubricated systems, pressure lubrication delivers oil precisely where it's needed. This reduces friction, wear, and heat in high-stress, continuous-duty environments.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eCast Iron Pump Construction\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eCast Iron Major Components:\u003c\/b\u003e The crankcase, cylinder heads, cylinders, connecting rods, crankshaft, and high-pressure piston are all cast iron, for durability and rigidity that aluminum components do not offer.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eRebuildable Connecting Rods:\u003c\/b\u003e The CNC-machined solid cast iron connecting rods use replaceable bearing inserts and wrist pins, so the assembly is fully rebuildable rather than throw-away.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eFour-Ring Piston Design:\u003c\/b\u003e Each piston has two oil control rings and two compression rings, designed to overlap. This design maximizes sealing, minimizes compression loss, reduces oil carryover, and extends ring life.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eTwo-Stage Pump:\u003c\/b\u003e The model APP3Y2062TP pump uses aluminum low-pressure pistons for balance and efficiency, since they operate at around 45 PSI. Cast iron high-pressure pistons resist cylinder scoring under heavy loads.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eNon-Oil-Absorbent Gaskets:\u003c\/b\u003e High-quality gaskets minimize oil leakage and reduce maintenance requirements.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eLong Pump Life:\u003c\/b\u003e Estimated pump life is 70,000 hours.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eDrive and Motor\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eHeavy-Duty Cast Iron Flywheel:\u003c\/b\u003e The flywheel's increased mass generates greater kinetic energy, which reduces amp draw and lowers energy consumption. Multiple B-groove belts extend belt life, and optimized cooling fins enhance pump cooling.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eBelt Tensioner:\u003c\/b\u003e An included belt tensioner helps maintain proper belt tension.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eTEFC Motor:\u003c\/b\u003e The totally enclosed fan-cooled motor runs at 1740 RPM, driving the pump at 815 RPM.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eMagnetic Starter:\u003c\/b\u003e The unit is equipped with a mag starter. FLA with the 1.15 service factor is 41.9 amps, and the recommended breaker is 70 amps.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eContinuous Run and Included Equipment\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eContinuous Run:\u003c\/b\u003e The compressor is configured for continuous-run operation. Head unloaders relieve the intake valve during operation, improving pump cooling and reducing wear under heavy workloads.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003e115 CFM Refrigerated Air Dryer:\u003c\/b\u003e A 115 CFM refrigerated air dryer is bundled with the compressor.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eAutomatic Tank Drain:\u003c\/b\u003e An auto drain handles condensate removal from the tank.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eIsolator Pads and Pump Riser:\u003c\/b\u003e Isolator pads are included, and the pump is mounted on a riser.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eCertified Tank:\u003c\/b\u003e The 120-gallon vertical tank has a 1\" outlet and carries ETL, ASME, and CRN certifications.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cb\u003eService Kit:\u003c\/b\u003e The matching service kit is EFKIT009AWB.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed help confirming this 15 HP, 208V three-phase compressor and dryer package is the right fit for your air demand and electrical service? Call Pittsburgh Spray Equipment at 888-714-1410 for sizing help.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSpecifications — ESP15V120Y3-208\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHP\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTank Size\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eVoltage +\/- 10%\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePhase\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDrive Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eElectric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTank Drain\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePump Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCFM\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e58.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSilent Air\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSmart Air\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCompressor Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePiston\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMotor Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTank Orientation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOutlet Size\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBelt Count\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePump Stage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePump Model\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eAPP3Y2062TP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePump Riser\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBelt Tensioner\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMag Starter\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRadiator\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePeak Starting Amps\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e237.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePump RPM\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e815.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMotor RPM\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1740.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eFLA + 1.15 Service Factor\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e41.90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eLocked Rotor Amps\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e237.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRecommended Breaker\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e70.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMax PSI\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e175.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCrated Length\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCrated Width\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e46\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOil Capacity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOil U\/M\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eQuarts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eStart Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eFIXED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eEstimated Pump Life (Hours)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e70000.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCertifications\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eETL,ASME,CRN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eService Kit\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEFKIT009AWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"EMAX","offers":[{"title":"Default Title","offer_id":67647995969727,"sku":"ESP15V120Y3-208","price":8092.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0019\/0880\/1571\/files\/ESP15V120Y3-208-1-3-scaled.jpg?v=1791869601","url":"https:\/\/ca.pittsburghsprayequip.com\/products\/emax-esp15v120y3-208-silent-air-industrial-plus-15hp-3cyl-57cfm-3-phase-208v-2-stage-120-gal-vertical-stationary-electri","provider":"Pittsburgh Spray","version":"1.0","type":"link"}